CONFINED SPACE / BAR HOLE / LEAK DETECTOR
GX-2003 Model
Gas Detection For Life
World Leader In Gas Detection & Sensor Technology
www.rkiinstruments.com
RKI Instruments, Inc. • 33248 Central Ave. Union City, CA 94587 • Phone (800) 754-5165 • (510) 441-5656 • Fax (510) 441-5650
Features
• Threeoperatingmodes:
Normal, Bar Hole, and Leak Check
•
Monitors LEL, and % volume methane,
O2, CO and H2S
• Barholemodetestsforpeakmethaneandoxygenlevels
• Leakdetectmodeoffershighsensitivitytestsforppm
level natural gas leaks
• 0to100%volumeMethane
• Auto-rangingdisplayof%volumeand%LEL
• Internalsampledrawingpumpwithupto40footrange
• Vibration,visual,andaudiblealarms
• Automaticbacklightduringalarms
• Calibrationreminderwithlockoutoption
• Ni-MHoralkalinepowersource(interchangeable)
• Quickcharge(completechargein90minutes)
• Glovefriendlyglowinthedarkbuttons
• Alarmlatchingornon-latching
• Highimpactprotectiverubberboot
• Upto600hoursofdataloggingwithalarmtrends
• Autocalibrationorsinglecalibration
• TWAandSTELreadingswithlunch-breakmode
• Intrinsicallysafe,CSA,C/USclassified
• 2yearwarranty
Builtaroundhigh-qualitymicro-sensortechnology,theGX-2003isRKI’ssmallestpersonal5-in-1gasmonitorwithabuilt
insamplepump.Weighingonly11ounces,ithasmanyfeatureswhichsettheGX-2003apartfromthecompetition.For
example,itcanmonitorthestandardconfinedspacegases(LELcombustibles,Oxygencontent,CarbonMonoxide,and
HydrogenSulfide),anditcanalsomeasure100%volumeMethaneanddynamicallydisplayeither%LEL,or%volume
withitsauto-rangingability.
TheGX-2003’slargeLCDdisplayshowsallgasreadings,batterylevel,currenttime,andwillautomaticallybacklightin
alarmconditions.Thisunitalsohasaspecialbarholemodetofacilitatelocatingundergroundgasleaks.Ahighsensitivity
leak check mode is alsoincluded, and provides ppm leveldetection of gas leaks. A special variablefrequency alarm
helpstopinpointtheleakwithoutlookingattheinstrumentdisplay.Otherstandardmodealarmtypesincludevibration,
visual, and audible alarms that can be set to latching or non-latching. Controlled by a microprocessor, the GX-2003
continuouslychecksitselfforsensorconnections,lowbattery,circuittrouble,lowflow,andcalibrationerrors.TheGX-2003
caninterchangeablyoperateoneitheraNi-MHbatterypackor3AAalkalinebatteries.Thebatteriesaresimpletoreplace
requiringnotoolstoaccessthebatterycompartment.TheNi-MHbatterypackcanreceiveachargedirectlywithinthe
instrumentorseparately,allowingtheunittoremaininservice.
Calibration intervals and reminders areuser adjustable and can be set to eithergo into alarm or to lock the userout
of normal measurement mode once a calibration period has expired. Calibrations can be performed automatically or
individually in single calibration mode. The GX-2003 is also compatible with the economical SM-2003 single channel
calibrationstation.