PT0E-0980
Portable Gas Monitor
GX-8000
Operating Manual
(PT0-098)
Request for the Customers
Read and understand this operating manual before using the gas monitor.
Use the gas monitor in accordance with the operating manual.
Regardless of warranty period, we shall not make any compensation for accidents and
damage caused by using this product.
The compensation shall be made only under the warranty policy of products or parts
replacement.
Because this is a safety unit, a regular maintenance for every six months and regular
maintenance must be performed.
If any abnormality was found in the gas monitor, notify them to RIKEN KEIKI immediately.
Zobrazit stránku 0
1 2 3 4 5 6 ... 51 52

Shrnutí obsahu

Strany 1 - GX-8000

PT0E-0980 Portable Gas Monitor GX-8000 Operating Manual (PT0-098) Request for the Customers • Read and understand this operating m

Strany 2 - Safety information

3 Product Components 3-2. Names and functions for each part GX-8000 - 10 - NOTE There are the following two combinations of battery units. The f

Strany 3 - <Contents>

3 Product Components 3-2. Names and functions for each part - 11 - GX-8000 (1) LCD display Displays gas concentrations, alarms, etc. (2) Buzzer

Strany 4 - Outline of the Product

3 Product Components 3-2. Names and functions for each part GX-8000 - 12 - <LCD Display> (1) Pilot indicator Displays the op

Strany 5 - Important Notices on

4 How to Use 4-1. Before using the gas monitor - 13 - GX-8000 4 How to Use 4-1. Before using the gas monitor Not only the first-time user

Strany 6 - 2-2. Warning cases

4 How to Use 4-2. Preparation for start-up GX-8000 - 14 - (1) Open the recharging jack cover of the gas monitor. (2) Put the plug of the

Strany 7 - 2-3. Precautions

4 How to Use 4-2. Preparation for start-up - 15 - GX-8000 <Attaching Batteries> (when the optional unit BUD-8000(G) is used) When the gas mo

Strany 8

4 How to Use 4-2. Preparation for start-up GX-8000 - 16 - CAUTION • Turn off the power of the gas monitor before replacing the battery unit

Strany 9 - Product Components

4 How to Use 4-2. Preparation for start-up - 17 - GX-8000 <Connection of Gas Sampling Probe and Gas Sampling Hose> • Attach the gas sampling

Strany 10 - <Outline Drawing>

4 How to Use 4-3. Basic operating procedures GX-8000 - 18 - 4-3. Basic operating procedures Normally, the detection mode is used for normal oper

Strany 11 - CAUTION

4 How to Use 4-4. How to start the gas monitor - 19 - GX-8000 4-4. How to start the gas monitor <<Start-up Procedure>> Keep the POWER

Strany 12 - <LCD Display>

Safety information The Portable Gas Monitor Model GX-8000 is a gas monitor designed to provide continuous exposure monitoring of combustible gas, o

Strany 13 - How to Use

4 How to Use 4-4. How to start the gas monitor GX-8000 - 20 - ↓ STEL Alarm Setpoint Display ↓ TWA Alarm Setpoint Display ↓

Strany 14

4 How to Use 4-5. How to detect - 21 - GX-8000 4-5. How to detect In the detection mode, put the gas sampling probe close to the detection area an

Strany 15

4 How to Use 4-5. How to detect GX-8000 - 22 - NOTE • If the combustible gas reading exceeds 100% LEL, the CO reading rises t

Strany 16

4 How to Use 4-5. How to detect - 23 - GX-8000 <Manual Memory> Any instantaneous value during measurement can be recorded. Up to 256 points

Strany 17

4 How to Use 4-5. How to detect GX-8000 - 24 - <Auto Range Switching Point> (TYPES-A and E Only) If Auto Range is set on a type with the v

Strany 18 - GX-8000 - 18

4 How to Use 4-6. Modes - 25 - GX-8000 4-6. Modes Details on each mode are provided as follows. (* Operations are slightly different depending on

Strany 19 - - 19 - GX-8000

4 How to Use 4-7. Air calibration mode GX-8000 - 26 - 4-7. Air calibration mode Press the AIR switch. Keep pressing the AIR

Strany 20

4 How to Use 4-7. Air calibration mode - 27 - GX-8000 NOTE • Air calibration can be performed even when there is a gas alarm. • If the air calib

Strany 21 - 4-5. How to detect

4 How to Use 4-8. Display/setting mode GX-8000 - 28 - 4-8. Display/setting mode This mode allows you to change various displays and settings. Ev

Strany 22

4 How to Use 4-8. Display/setting mode - 29 - GX-8000 NOTE The gas monitor automatically returns to the detection mode in about 20 seconds if the

Strany 23 - <Manual Memory>

GX-8000 - 3 - <Contents> 1 Outline of the Product...

Strany 24

4 How to Use 4-8. Display/setting mode GX-8000 - 30 - <Combustible Gas Measurement Range Setting "HC RANGE"> (TYPES-A and E Only)

Strany 25 - 4-6. Modes

4 How to Use 4-8. Display/setting mode - 31 - GX-8000 NOTE During vol% range-only measurement, "vol%" and "No A

Strany 26 - 4-7. Air calibration mode

4 How to Use 4-8. Display/setting mode GX-8000 - 32 - <Full Scale Display/Alarm Setpoint Display/Alarm Test "ALARM-P"> Display t

Strany 27 - - 27 - GX-8000

4 How to Use 4-8. Display/setting mode - 33 - GX-8000 <Pump ON/OFF Setting "PUMP OFF"> Used to turn on/off the pump operations.

Strany 28 - 4-8. Display/setting mode

4 How to Use 4-8. Display/setting mode GX-8000 - 34 - <ID Display/Selection "ID SELECT"> Display an ID if it has been registered

Strany 29 - - 29 - GX-8000

4 How to Use 4-9. How to exit - 35 - GX-8000 <Log Data Display "REC.DATA"> Display concentration data recorded to the manual memor

Strany 30 - GX-8000 - 30

5 Operations and Functions 5-1. Gas alarm activation GX-8000 - 36 - 5 Operations and Functions 5-1. Gas alarm activation Gas alarm: Tr

Strany 31

5 Operations and Functions 5-1. Gas alarm activation - 37 - GX-8000 <Display Operation> Gas Concentration Display In a gas alarm, the gas co

Strany 32 - GX-8000 - 32

5 Operations and Functions 5-2. Fault alarm activation GX-8000 - 38 - 5-2. Fault alarm activation Fault alarm: Triggered when an abnormality is

Strany 33

6 Maintenance 6-1. Maintenance intervals and items - 39 - GX-8000 6 Maintenance This is an important instrument for the purpose of safety.

Strany 34 - GX-8000 - 34

1 Outline of the Product 1-1. Preface GX-8000 - 4 - 1 Outline of the Product 1-1. Preface Thank you for choosing our portable gas monit

Strany 35 - 4-9. How to exit

6 Maintenance 6-2. Gas calibration method GX-8000 - 40 - <About Maintenance Services> • We provide services on regular maintenance includ

Strany 36 - Operations and Functions

6 Maintenance 6-3. How to clean - 41 - GX-8000 6-3. How to clean Clean the gas monitor if it becomes extremely dirty. The gas monitor must be turn

Strany 37 - WARNING

6 Maintenance 6-4. Parts replacement GX-8000 - 42 - How to replace the activated carbon filter (1) Using a coin, etc., turn the a

Strany 38 - 5-3. Other functions

6 Maintenance 6-4. Parts replacement - 43 - GX-8000 <Replacement of Regular Replacement Parts> List of recommended regular replacement parts

Strany 39 - Maintenance

7 Storage and Disposal 7-1. Procedures to store the gas monitor or leave it for a long time GX-8000 - 44 - 7 Storage and Disposal 7-1. P

Strany 40 - 6-2. Gas calibration method

7 Storage and Disposal 7-3. Disposal of products - 45 - GX-8000 7-3. Disposal of products WARNING • Do not disassemble the electro

Strany 41 - 6-4. Parts replacement

8 Troubleshooting GX-8000 - 46 - 8 Troubleshooting The troubleshooting does not explain the causes of all the malfunctions which occur o

Strany 42

8 Troubleshooting - 47 - GX-8000 Symptoms Causes Actions Water or oil, etc. was drawn in. Check the gas sampling hose for any damage or mark of d

Strany 43

9 Product Specifications 9-1. List of specifications GX-8000 - 48 - 9 Product Specifications 9-1. List of specifications <Japanese S

Strany 44 - Storage and Disposal

9 Product Specifications 9-1. List of specifications - 49 - GX-8000 <Overseas Specifications> Detection principle Galvanic cell type (OS) N

Strany 45 - 7-3. Disposal of products

2 Important Notices on Safety 2-1. Danger cases - 5 - GX-8000 2 Important Notices on Safety 2-1. Danger cases

Strany 46 - Troubleshooting

9 Product Specifications 9-2. List of accessories GX-8000 - 50 - 9-2. List of accessories Standard accessories • Li-ion battery unit (BUL-8000

Strany 47 - - 47 - GX-8000

10 Definition of Terms 9-2. List of accessories - 51 - GX-8000 10 Definition of Terms vol% Gas concentration indicated in the unit of one

Strany 48 - Product Specifications

GX-8000 - 52 - Warranty Policy RIKEN KEIKI CO., LTD., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship

Strany 49

2 Important Notices on Safety 2-2. Warning cases GX-8000 - 6 - 2-2. Warning cases WARNING Sampli

Strany 50 - 9-2. List of accessories

2 Important Notices on Safety 2-3. Precautions - 7 - GX-8000 2-3. Precautions CAUTION Do not

Strany 51 - Definition of Terms

2 Important Notices on Safety 2-3. Precautions GX-8000 - 8 - CAUTION Others • Pressing buttons unnecessarily may change the settings, prev

Strany 52 - Warranty Policy

3 Product Components 3-1. Main unit and standard accessories - 9 - GX-8000 3 Product Components 3-1. Main unit and standard accessories A

Komentáře k této Příručce